5 adjusting online and offline interconnection, 5 adjusting online and offline interconnection 7, 17 working with the fb editor – Lenze 8400 User Manual

Page 1147

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1147

17

Working with the FB Editor

17.5

Adjusting online and offline interconnection

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.5

Adjusting online and offline interconnection

If the »Engineer« detects that online and offline interconnection differ from each other, the

Compare interconnection dialog box is displayed with various options for the adjustment:

Tip!

The dialog box can also be opened via the

symbol in the FB Editor toolbar.

Button

Function

Accepting the interconnection from

the device

Add the interconnection in the device to the FB Editor. The interconnection

existing in the FB Editor will be overwritten by this action.

Transferring the interconnection to

the device

Transfer the offline interconnection which is currently not visible in the FB

Editor to the device. The interconnection existing in the device will be

overwritten by this action.

Showing differences

Showing differences between online and offline interconnection.

Cancel

Close the Adjust interconnection dialog box without making an adjustment.

Advertising