2 profile entry, Profile entry, Pter – Lenze 8400 User Manual

Page 517: Profile, Entry, 8basic drive functions (mck)

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

517

8

Basic drive functions (MCK)

8.8

Positioning

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.8.2.2

Profile entry

In the »Engineer«, the following parameterisation dialog is available for setting the profile

parameters:

A profile is described by the following profile parameters:

Icon

Profile parameter
(Standard) profile

Profile data set (profile numbers 1 ... 15), in which the profile data are stored.
Mode (

C01300/1...15

)

Selection of the way in which positioning is to be carried out.

Positioning modes ( 520)

Position (

C01301/1...15

)

Target position or distance to be traversed.

When the position is indicated, a distinction is made between absolute position and relative position:

• An absolute position always indicates the distance to the defined zero position:

Absolute position = Target position

• A relative position indicates the distance to the starting position (current position):

Relative position = Target position - Starting position

A

10

20

30

40

50

60

70

80

90

100

10

30

80

P1

P2

P3

0

10

20

30

40

50

60

70

80

90

100

10

20

50

P3

P2

P1

0