18.1.146

L_RLQ_1

This FB links a selected direction of rotation to the quick stop function with wire-break protection.

Inputs

Outputs

Function

[18-63] Truth table of the FB L_RLQ, 0 = FALSE, 1 = TRUE

Identifier

Data type

Information/possible settings

bCw

BOOL

Input

• TRUE = CW rotation

bCCw

BOOL

Input

• TRUE = CCW rotation

Identifier

Data type

Value/meaning

bQSP

BOOL

Output signal for quick stop (QSP)

bCwCcw

BOOL

Output signal for CW/CCW rotation

• TRUE = CCW rotation

Inputs

Outputs

Notes

bCw

bCCw

bCwCcw

bQSP

TRUE

TRUE

FALSE

TRUE

The inputs have this status only if a TRUE signal is being applied to

both inputs at the moment of switch-on!

See also FB illustration above, "Init" = 1.

If one of the inputs has the TRUE status, the following truth table applies:

FALSE

FALSE

FALSE

TRUE

See also FB illustration above, "Init" = 0.

TRUE

FALSE

FALSE

FALSE

FALSE

TRUE

TRUE

FALSE

TRUE

TRUE

X (save)