C00711/5

0: Not connected

LA_TabPos

: bJogSpeed1

Control input for fixed speed selection value 1

C00711/6

0: Not connected

LA_TabPos

: bJogSpeed2

Control input for fixed speed selection value 2

C00711/7

0: Not connected

LA_TabPos

: bMPotEnable

Control input for activation of motor potentiometer

C00711/8

0: Not connected

LA_TabPos

: bMPotUp

Control input for motor potentiometer ramp-up

C00711/9

0: Not connected

LA_TabPos

: bMPotDown

Control input for motor potentiometer ramp-down

C00711/10

0: Not connected

LA_TabPos

: bMBrakeRelease

Control input for manual holding brake release request

C00711/11

0: Not connected

LA_TabPos

: bPosCtrlOn

Control input for activation of position controller

C00711/12

0: Not connected

LA_TabPos

: bLimitSwitchPos

Input for positive hardware limit switch signal

C00711/13

0: Not connected

LA_TabPos

: bLimitSwitchNeg

Input for negative hardware limit switch signal

C00711/14

0: Not connected

LA_TabPos

: bReleaseLimitSwitch

Control input for hardware limit switch retracting

request

C00711/15

0: Not connected

LA_TabPos

: bManJogPos

Control input for manual jog in positive direction request

C00711/16

0: Not connected

LA_TabPos

: bManJogNeg

Control input for manual jog in negative direction

request

C00711/17

0: Not connected

LA_TabPos

: bManEnable2ndSpeed

Control input for activation of the second manual speed

for manual jog

C00711/18

0: Not connected

LA_TabPos

: bEnableSpeedOverride

Control input for activation of speed override

C00711/19

0: Not connected

LA_TabPos

: bEnableAccOverride

Control input for activation of acceleration override

C00711/20

0: Not connected

LA_TabPos

: bHomeStartStop

Control input for start/stop homing

C00711/21

0: Not connected

LA_TabPos

: bHomeSetPosition

Control input for setting the home position

C00711/22

0: Not connected

LA_TabPos

: bHomeResetPosition

Control input for reset of "Home position known"

C00711/23

0: Not connected

LA_TabPos

: bHomeMark

Input for pre-stop signal for homing

C00711/24

0: Not connected

LA_TabPos

: bPosSetProfilePosition

Control input for accepting the profile position in the

profile data set

C00711/25

0: Not connected

LA_TabPos

: bPosSetActualPosition

Control input for accepting the current position in the

profile data set

C00711/26

0: Not connected

LA_TabPos

: bPosExecute

Control input for positioning start

C00711/27

0: Not connected

LA_TabPos

: bPosFinishTarget

Control input for completion of positioning to target

position