1 digital terminals, Digital terminals, 6i/o terminals – Lenze 8400 User Manual
Page 303
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
303
6
I/O terminals
6.1
Digital terminals
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.1
Digital terminals
The controller is equipped with six parameterisable inputs (DI1 ... DI6) at the sockets X41 ... X43 for
detecting digital signals.
Tip!
The two inputs DI3 and DI4 (pin 4 and pin 2 of the X42 socket) can be reconfigured
alternatively to digital outputs (DO1/DO2) by a corresponding parameter setting.
Reconfiguring DI3(4) to output DO1(2)
Parameterisation dialog in the »Engineer«:
Note!
Initialisation behaviour:
• After mains switching up to the start of the application, the digital outputs remain set
to FALSE.
Exception handling:
• In case of a critical exception in the application (e.g. reset), the digital outputs are set
to FALSE considering the terminal polarity parameterised in