18.1

Function blocks | L_SignalMonitor_b

1398

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.152

L_SignalMonitor_b

This FB outputs four binary signals which can be selected from a list of binary output signals of all

function blocks provided in the device.

• Inversion of the output signals can be set.

Outputs

Parameter

Identifier

Data type

Value/meaning

bOut1

...

bOut4

BOOL

Output signal

FALSE / TRUE

Parameter

Possible settings

Info

C00411/1

...

C00411/4

See

selection list - digital signals

Selection of the signal sources for

bOut1 ... bOut4

C00412

Value is bit-coded:

Inversion

• Bit set = inversion active

Bit 0

bOut1 inverted

Bit 1

bOut2 inverted

Bit 2

bOut3 inverted

Bit 3

bOut4 inverted

Bit 4

Reserved

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved