Message, Ck08: home position unknown, Xx.0184.00156 – Lenze 8400 User Manual

Page 607: Xx.0184.08005, Xx.0184.08007, Xx.0184.08009, Xx.0184.08014, 9diagnostics & error management

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

607

9

Diagnostics & error management

9.10

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Ck08: Home position unknown [xx.0184.00156]

Ck09: Positioning mode invalid [xx.0184.08005]

Ck10: Implausible profile data [xx.0184.08007]

Ck11: Invalid operating mode [xx.0184.08009]

Ck12: Invalid profile number [xx.0184.08014]

Response (Lenze setting printed in bold)

Setting:

C00595/8

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: Home position is unknown.

Perform homing.

Response (Lenze setting printed in bold)

Setting:

C00595/9

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The positioning mode defined via the

wPosProfileMode input is not supported.

Define a valid positioning mode.

Response (Lenze setting printed in bold)

Setting:

C00595/10

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Cause 1: The profile data result in a braking distance that

is longer than the distance to be travelled.

• Occurs if a small specified distance within a few

increments is to be positioned with final speed and S

rounding.

• It has been detected that the braking distance

required for sizing the profile phases correctly

regarding the S rounding and overchange is longer

than the selected distance in the first cycle when

bExecute = TRUE.

Cause 2: Reversing process in overchange profile linkage

• If the linkage of two profiles with final speed causes a

reversing process in the second profile and this is to

smooth another sequence profile with final speed

too, the error is set and ramped down to standstill.

Cause 3: Final speed at overchange is higher than

maximum profile speed

On cause 1:

• Set the S rounding to zero for the respective profile

and go to the next profile with final speed zero.

On cause 2:

• The continuous profile linkage with overchange must

not provide any reversing process due to the profile

selection. Here, the profile which causes a reversing

must be defined with the final speed 0.

On cause 3:

• Profiles in an overchange profile linkage with final

speeds higher than their max. profile speeds are not

supported. The final speed of a profile is limited

internally to the max. profile speed in the profile data

set.

Response (Lenze setting printed in bold)

Setting:

C00595/11

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The operating mode defined via the

wMckOperationMode input is not supported.

Define a valid operating mode.

Response (Lenze setting printed in bold)

Setting:

C00595/12

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

MCK: The positioning profile number in the positioning

operating mode specified via the wPosProfileNo input is

invalid.

Define a valid profile number.

Advertising