Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

885

16

Parameter reference

16.2

Parameter list | C00711

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00711/28

0: Not connected

LA_TabPos

: bPosDisableFollowProfile

Control input for suppression of sequence profile linkage

C00711/29

0: Not connected

LA_TabPos

: bPosStop

Control input for interruption of profile generation by

ramp-down procedure

C00711/30

0: Not connected

LA_TabPos

: bGPAnalogSwitchSet

Control input for analog-value selector change-over

C00711/31

0: Not connected

LA_TabPos

: bGPDigitalDelayIn

Input for digital signal with time delay

C00711/32

0: Not connected

LA_TabPos

: bGPLogicIn1

Input signal 1 for digital logic

C00711/33

0: Not connected

LA_TabPos

: bGPLogicIn2

Input signal 2 for digital logic

C00711/34

0: Not connected

LA_TabPos

: bGPLogicIn3

Input signal 3 for digital logic

C00711/35

0: Not connected

LA_TabPos

: bGPDFlipFlop_InD

Control input for DFlipFlop setting signal

C00711/36

0: Not connected

LA_TabPos

: bGPDFlipFlop_InClk

Control input for DFlipFlop clock signal

C00711/37

0: Not connected

LA_TabPos

: bGPDFlipFlop_InClr

Control input for DFlipFlop reset signal

C00711/38

0: Not connected

LA_TabPos

: bGPCounter1ClkUp

Control input for up-counting counter module 1

C00711/39

0: Not connected

LA_TabPos

: bGPCounter1ClkDown

Control input for down-counting counter module 1

C00711/40

0: Not connected

LA_TabPos

: bGPCounter1Load

Control input for load value acceptance in counter

module 1

C00711/41

0: Not connected

LA_TabPos

: bMckOperationMode_1

Control input for MCK operating mode changeover value

1

C00711/42

0: Not connected

LA_TabPos

: bMckOperationMode_2

Control input for MCK operating mode changeover value

2

C00711/43

0: Not connected

LA_TabPos

: bMckOperationMode_4

Control input for MCK operating mode changeover value

4

C00711/44

0: Not connected

LA_TabPos

: bMckOperationMode_8

Control input for MCK operating mode changeover value

8

C00711/45

0: Not connected

LA_TabPos

: bPosProfileNo_1

Control input for selection of profile number value 1

C00711/46

0: Not connected

LA_TabPos

: bPosProfileNo_2

Control input for selection of profile number value 2

C00711/47

0: Not connected

LA_TabPos

: bPosProfileNo_4

Control input for selection of profile number value 4

C00711/48

0: Not connected

LA_TabPos

: bPosProfileNo_8

Control input for selection of profile number value 8

C00711/49

0: Not connected

LA_TabPos

: bFreeIn1

Input for binary user signal 1

C00711/50

0: Not connected

LA_TabPos

: bFreeIn2

Input for binary user signal 2

Parameter | Name:

C00711 | LA_TabPos: Digital connection list

Data type: UNSIGNED_16

Index: 23864

d

= 5D38

h