7technology applications – Lenze 8400 User Manual

Page 399

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

399

7

Technology applications

7.3

TA "Table positioning"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Output words

Name

Assignment

Word 1 DriveControlStatus

Status word

• For bit assignment, see table below.

Word 2 GPSignalOut1

Analog signal monitor: Output signal 1

• The selection of the signal source to output is executed in

C00410/1

.

• Gain and offset for the output signal can be parameterised in

C00413/1

and

C00413/2

.

• For a detailed functional description see

the

L_SignalMonitor_a

FB.

Word 3 and 4 SetPos

Absolute position setpoint in [increments]

• 65535 [Increments] ≡ 1 motor revolution

• The position resolution, i.e. how many increments form one

unit, is displayed in

C01205

.

Word 5 MotorSpeedAct

Actual speed value

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

• Only available for control mode "40: MCI".

Word 6 ... 16 -

Not preconfigured

• Only available for control mode "40: MCI".

Status word

Name

Status

Bit 0 DriveFail

1 ≡ Drive controller in error status

"

Fault

" device status is active.

Bit 1 GPSignalOut1

Binary signal monitor: Output signals 1 & 2

• The signal sources to be output are selected in

C00411/1...2

.

• A bit coded inversion of the output signals can be

parameterised in

C00412

.

• For a detailed functional description see

FB

L_SignalMonitor_b

.

Bit 2 GPSignalOut2

Bit 3 CInhActive

1 ≡ Controller inhibit is active

Bit 4 DriveReady

1 ≡ Drive controller is ready for operation

"

SwitchedOn

" device status is active.

• The drive is in this device status if the DC bus voltage is

applied and the controller is still inhibited by the user

(controller inhibit).

Bit 5 DigitalInput5

Signal from the digital input DI5

Bit 6 DigitalInput6

Signal from the digital input DI6

Bit 7 -

Free status bit 7 (not assigned, freely assignable)

Bit 8 InTarget

1 ≡ Target position (actual value) is in the target window

Bit 9 ProfileBusy

1 ≡ Profile positioning is active

Bit 10 HomePosAvailable

1 ≡ Home position is known

Bit 11 SpeedActCompare

Result of the speed comparison (detection of speed=0)

• In case of the "Open loop" operation:

1 ≡ Speed setpoint < comparison value (

C00024

)

• For "Closed loop" operation:

1 ≡ actual speed value < comparison value (

C00024

)

Bit 12 DigitalInput4

Signal from the digital input DI4

Bit 13 DigitalInput3

Signal from the digital input DI3

Bit 14 QSPIsActive

1 ≡ Quick stop is active

Bit 15 -

Free status bit 15 (not assigned, freely assignable)

Advertising