4 interface to safety system, Interface to safety system, Subchapt – Lenze 8400 User Manual

Page 453: Safe stop 1 (ss1), 8basic drive functions (mck)

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

453

8

Basic drive functions (MCK)

8.2

Internal interfaces | System block "LS_MotionControlKernel"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.2.4

Interface to safety system

For operation with optional safety system, the

LS_MotionControlKernel

system block has the

wSMCtrl input, This interface is used to transfer a control word by means of which the Motion

Control Kernel can be supplied with information on requested or active safety functions. The

Motion Control Kernel then initiates the necessary motion sequence (e.g. braking).
At the moment, only bit 0 in the wSMCtrl control word has a function. Additional functions are in

preparation:

Behaviour in case of request for "Safe Stop 1" (SS1)
The drive is brought to a standstill with the stopping ramp set in

C02610/3

.

[8-5]

Ramping down to standstill

If the request is reset during the down-ramping process (bit 0 = "10"), the behaviour depends on

the active operating mode:

• In the "

Speed follower

" operating mode, direct synchronisation with the target speed takes

place with the ramp time set in

C02610/2

.

• In the "

Homing

" operating mode, the ramp-down is continued with the deceleration for stop set

in

C01251

if the bit 8 ("HomStartStop") in the MCK control word = "0". If bit 8 is set, the homing

process starts immediately in the selected homing mode.

• In the "

Manual jog

" operating mode, the behaviour depends on whether the manual jog

initiator (bManJogPos or bManJogNeg) is still set:

• In the "

Positioning

" operating mode, the behaviour depends on the setting in

C01216

.

• In the "

Position follower

" operating mode, (forward) positioning to the signalled absolute

position always takes place if this position differs from the internal position.

Bit

Designation

Description

0 SafeStop1

"1" ≡ Request for "Safe Stop 1" (SS1).

1

...

15

Reserved

In preparation - Still without function!

• The time set in

C02610/3

refers to the down-

ramping of the reference speed set in

C00011

.

• If the current speed is lower, the time to

standstill is accordingly lower as well.

n

t

C00011

C02610/3

SS1

Bit 0

(SafeStop1)

bManJogPos

bManJogNeg

Behaviour

1

TRUE

Ramping down to standstill

0

TRUE

Accelerating to manual speed

0

FALSE

Ramping down to standstill

Advertising