C00570

C00572

C00574

Parameter | Name:

C00570 | Resp. to controller limitations

Data type: UNSIGNED_8

Index: 24005

d

= 5DC5

h

Configuration of monitoring of the motor control (group 2)
Selection list

0 No Reaction
1 Fault
5 Warning

Subcodes

Lenze setting

Info

C00570/1

0: No Reaction

Response if direct-axis current controller is limited

• e.g. at servo control (

SC

)

C00570/2

0: No Reaction

Response if cross current controller is limited

• e.g. at servo control (

SC

)

C00570/3

0: No Reaction

Response if torque setpoint is limited

• Limitation of the speed controller output, the

differential setpoint precontrol, and of the additive

torque at (

SC

) servo control and (

SLVC

) sensorless

vector control.

C00570/4

0: No Reaction

Response if field controller is limited

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00572 | Brake resistor overload threshold

Data type: UNSIGNED_8

Index: 24003

d

= 5DC3

h

Adjustable threshold for monitoring the brake resistor utilisation

• The response for reaching the threshold can be selected in

C00574

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 100 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00574 | Resp. to brake resist. overtemp.

Data type: UNSIGNED_8

Index: 24001

d

= 5DC1

h

Response which is triggered if the threshold set in

C00572

for monitoring brake resistor utilisation is reached.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1