92 l_gainoffsetphip_1, 92 l_gainoffsetphip_1 8, L_gainoffsetphip_1 – Lenze 8400 User Manual

Page 1298: 18 function library

Advertising
background image

18

Function library

18.1

Function blocks | L_GainOffsetPhiP_1

1298

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.92

L_GainOffsetPhiP_1

This FB can amplify an angle signal and add an offset to it afterwards.

• The internal calculations (addition and subtraction) are carried out with 32 bits without

overflow/underflow. Division is not remainder considered.

• Gain and offset are selected via parameters.

• The value provided at the dnOut_p output is internally limited to ±2

31

-1.

Inputs

Outputs

Parameter

Function

Identifier

Data type

Information/possible settings

dnIn_p

DINT

Input signal

Identifier

Data type

Value/meaning

dnOut_p

DINT

Output signal

• Internal limitation to ±2

31

-1 (±2147483647)

Parameter

Possible settings

Info

C00678/1

-2147483647

Incr.

2147483647 Offset

• Lenze setting: 0 incr.

C00678/2

-2147483647

2147483647 Gain factor

• Lenze setting: 65536