7 l_analogswitch_4, L_analogswitch_4 4, L_analogswitch_4 – Lenze 8400 User Manual
Page 1164: 18 function library
Advertising
18
Function library
18.1
Function blocks | L_AnalogSwitch_4
1164
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.7
L_AnalogSwitch_4
This function block switches between two analog input signals. The switching is controlled via a
boolean input signal.
Inputs
Outputs
Identifier
Data type
Information/possible settings
nIn1_a
INT
Input signal 1
nIn2_a
INT
Input signal 2
bSet
BOOL
Selection of the input signal for the output to nOut_a
FALSE nIn1_a
TRUE nIn2_a
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal
/B$QDORJ6ZLWFKB
Q,QBD
Q2XWBD
Q,QBD
E6HW
Advertising