C01242 | mck: current pos profile number, C01242, 16 parameter reference – Lenze 8400 User Manual

Page 1008

Advertising
background image

16

Parameter reference

16.2

Parameter list | C01242

1008

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01242

Bit 16 DwellTime

Status bit - transient effects in target position active

• "1" ≡ Dwell time after reaching the setpoint position

is active.

Bit 17 InTarget

Status bit - actual position is in the target window

• "1" ≡ Dwell time has expired and current actual

position is in the set target window.

Bit 18 PosDone

Status bit - positioning process completed

• "1" ≡ Positioning profile has been completed in the

"Positioning" mode. Setpoint position is in target.

Bit 19 Reserved
Bit 20 ActPosMode_Bit00

Active positioning mode - status bit 0

Bit 21 ActPosMode_Bit01

Active positioning mode - status bit 1

Bit 22 ActPosMode_Bit02

Active positioning mode - status bit 2

Bit 23 ActPosMode_Bit03

Active positioning mode - status bit 3

Bit 24 ActProfileNo_Bit00

Active positioning profile - status bit 0

Bit 25 ActProfileNo_Bit01

Active positioning profile - status bit 1

Bit 26 ActProfileNo_Bit02

Active positioning profile - status bit 2

Bit 27 ActProfileNo_Bit03

Active positioning profile - status bit 3

Bit 28 ActProfileNo_Bit04

Active positioning profile - status bit 4

Bit 29 ActProfileNo_Bit05

Active positioning profile - status bit 5

Bit 30 ActProfileNo_Bit06

Active positioning profile - status bit 6

Bit 31 ActProfileNo_Bit07

Active positioning profile - status bit 7

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C01241 | MCK: Status word

Data type: UNSIGNED_32

Index: 23334

d

= 5B26

h

Parameter | Name:

C01242 | MCK: Current pos profile number

Data type: UNSIGNED_8

Index: 23333

d

= 5B25

h

Display of the current profile number of the active profile in the "Positioning" mode

Positioning

Display range

(min. value | unit | max. value)

0

255

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising