18 function library – Lenze 8400 User Manual
Page 1275
Advertising
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
1275
18
Function library
18.1
Function blocks | L_DigitalDelay_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Function
1. A FALSE-TRUE edge at bIn starts the internal timing element for the ON delay.
2. After the defined ON delay, the input signal bIn is output at bOut.
3. A TRUE-FALSE edge at bIn starts the internal timing element for the OFF delay.
4. After the defined OFF delay, the input signal bIn is output at bOut.
ON delay
OFF delay
Internal timing element for ON delay (retriggerable)
Internal timing element for OFF delay (retriggerable)
TRUE
FALSE
bOut
t
TRUE
FALSE
bIn
t
t
0
t
1