5 activate/deactivate quick stop, Activate/deactivate quick stop, Activate/deactivate quick stop ( 104) – Lenze 8400 User Manual

Page 104: 4device control (dctrl), 0rwru lqwhuidfh 0

Advertising
background image

4

Device control (DCTRL)

4.1

Device commands (C00002/x)

104

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.1.5

Activate/deactivate quick stop

The

C00002/17

= "1: On / start" device command activates the quick stop function, i.e. the motor

control is separated from the setpoint selection, and within the deceleration time parameterised

in

C00105

the motor is brought to a standstill (n

act

= 0).

From version 12.00.00

,

C00104/1

can be used to activate the position control during ramp-

down and/or at standstill if the following is provided:

• A position feedback system is set in

C00490

.

• The position control is activated (input bPosCtrlOn at the

LS_MotionControlKernel

system

block is set to TRUE, see the following configuration cutout).

• The inputs nPosCtrlOutLimit_a and nPosCtrlPAdapt_a at the

LS_MotorInterface

system block

are set to 100 %.

[4-1]

Activate required configuration for the "Position control during ramp-down and/or at standstill" function

• The motor is kept at a standstill during closed-loop operation.
• A pulse inhibit is set if the auto-DCB function has been activated via

C00019

.

The

C00002/17

= "0: Off / ready" device command deactivates the quick stop again, provided that

no other source of a quick stop is active.

Parameter

Info

Lenze setting

Value Unit

C00105

Decel. time - quick stop

2.000 s

Parameter

Info

Lenze setting

C00104/1

Bit 0: Standstill position-controlled

0

Bit 1: Ramp position-controlled

0

E3RV&WUO2Q

E3RV&WUO2Q

/6B0RWLRQ&RQWURO.HUQHO

E3RV&WUO2QB

"

/6B0RWRU,QWHUIDFH

"

0RWRU

LQWHUIDFH

0&.

Q3RV&WUO3$GDSWBD

Q3RV&WUO2XW/LPLWBD




758(