16 parameter reference – Lenze 8400 User Manual

Page 1054

Advertising
background image

16

Parameter reference

16.2

Parameter list | C02582

1054

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Bit 2  with hoist inv. feedfwd. control

Direction of feedforward control with vertical/hoist

technology:

• "0" ≡ Positive direction

• "1" ≡ Negative direction

Note:

Reversal (Ccw) is then considered.

Bit 3  Horizontal application

Direction of movement of the axis

• "0" ≡ The axis performs vertical movements.

Gravitational acceleration causes movements.

• "1" ≡ The direction of the axis is horizontal or rotary.

The gravitational acceleration does not cause any

movement.

Bit 4  Feedforward control C2581

From version 06.00.00

Selection of the feedforward control value

• "0" ≡ Automatic selection.

• The torque saved at the last stop is used.

• "1" ≡ Manual selection.

bMBrakeStartValue2 = FALSE: The feedforward

control value 1 set in

C02581/4

is used.

bMBrakeStartValue2 = TRUE: The feedforward

control value set in

C02581/5

is used.

Bit 5  Feedback monitoring

From version 06.00.00

Activation of status monitoring

• "1" ≡ The bMBrakeApplied input for status detection

of the brake (via a switching contact at the brake) is

monitored after the waiting time set in

C02589/3

has

expired.

Bit 6  SyncRampe L_NSet_1

From version 12.00.00

Selection of the ramp time for the synchronisation

process to setpoint speed after the brake opening time

has elapsed

Revised behaviour from version 12.00.00:

• "1" ≡ The ramp time of the effective acceleration of

the ramp function generator (

L_NSet_1

) is used

(Lenze setting).

• "0" ≡ As before, the ramp time set in

C02610/1

is used.

Note:

The changeover can be dynamically both via the ramp

parameter and via bit 6.

Bit 7  Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02582 | Holding brake: Setting

Data type: UNSIGNED_8

Index: 21993

d

= 55E9

h

Advertising