6i/o terminals, 1 digital terminals – Lenze 8400 User Manual
Page 325
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
325
6
I/O terminals
6.1
Digital terminals
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.1.3
Internal interfaces | System block "LS_DigitalOutput"
Both terminals DI3/DO1 and DI4/DO2 of the socket X42 can be optionally used as inputs or outputs.
• In the Lenze setting, both terminals are configured as digital input (DI3 and DI4).
• With a corresponding reconfiguration in
, the LS_DigitalOutput system block in the FB
Editor displays the digital outputs DO1 and DO2.
Input
DIS code | data type
Information/possible settings
bOut1
| BOOL
Digital output DO1
bOut2
| BOOL
Digital output DO2