Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

325

6

I/O terminals

6.1

Digital terminals

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.1.3

Internal interfaces | System block "LS_DigitalOutput"

Both terminals DI3/DO1 and DI4/DO2 of the socket X42 can be optionally used as inputs or outputs.

• In the Lenze setting, both terminals are configured as digital input (DI3 and DI4).
• With a corresponding reconfiguration in

C00116

, the LS_DigitalOutput system block in the FB

Editor displays the digital outputs DO1 and DO2.

Input

DIS code | data type

Information/possible settings

bOut1

C00444/1

| BOOL

Digital output DO1

bOut2

C00444/2

| BOOL

Digital output DO2