Parameter reference

16.2

Parameter list | C00507

844

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00507

C00516

Parameter | Name:

C00507 | Current password protection

Data type: UNSIGNED_16

Index: 24068

d

= 5E04

h

From version 06.00.00

Display of the currently active device access protection

Device access protection

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Only access to user menu
Bit 1 Parameter write protection
Bit 2 Parameter read protection
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved

Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Memory module binding on

Subcodes

Info

C00507/1

Password protection - all communication channels

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00516 | Checksums

Data type: UNSIGNED_32

Index: 24059

d

= 5DFB

h

This code is for device-internal use only and must not be written to by the user!