16 parameter reference – Lenze 8400 User Manual

Page 1100

Advertising
background image

16

Parameter reference

16.3

Table of attributes

1100

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02274

LS_WriteParamList: Frequency limitation

Linear value

22301

571D

A

8

UNSIGNED_16

1

C02275

LS_WriteParamList: Motor cable length

Linear value

22300

571C

A

4

UNSIGNED_16

10

C02276

LS_WriteParamList: Motor cable cross-

section

Linear value

22299

571B

A

4

UNSIGNED_16

100

C02278

LS_WriteParamList: PSM: Maximum

motor current field weakening

Linear value

22297

5719

A

4

UNSIGNED_16

100

C02279

LS_WriteParamList: Ultimate motor

current

Linear value

22296

5718

A

4

UNSIGNED_16

10

C02280

LS_WriteParamList: Max. motor speed

Linear value

22295

5717

A

4

UNSIGNED_16

1

C02281

LS_WriteParamList: VFC: Time const. slip

comp.

Linear value

22294

5716

A

4

UNSIGNED_16

1

C02284

LS_WriteParamList: VFC: limitation V/f

+encoder

Linear value

22291

5713

A

8

UNSIGNED_16

100

C02285

LS_WriteParamList: VFC: Vp V/f +encoder

Linear value

22290

5712

A

4

UNSIGNED_16

1000

C02286

LS_WriteParamList: VFC: Ti V/f +encoder

Linear value

22289

5711

A

4

UNSIGNED_16

10

C02287

LS_WriteParamList: VFC-ECO: Vp CosPhi

controller

Linear value

22288

5710

A

4

UNSIGNED_16

1000

C02288

LS_WriteParamList: VFC-ECO: Ti CosPhi

controller

Linear value

22287

570F

A

4

UNSIGNED_16

10

C02289

LS_WriteParamList: VFC-ECO: Minimum

voltage U/f

Linear value

22286

570E

A

4

INTEGER_16

100

C02290

LS_WriteParamList: VFC-ECO: Voltage

reduction ramp

Linear value

22285

570D

A

4

UNSIGNED_8

10

C02291

LS_WriteParamList: SLVC: Field current

controller gain

Linear value

22284

570C

A

4

INTEGER_16

100

C02292

LS_WriteParamList: SLVC: Cross current

controller gain

Linear value

22283

570B

A

4

INTEGER_16

100

C02293

LS_WriteParamList: Inverter motor brake:

nAdd

Linear value

22282

570A

A

4

INTEGER_16

1

C02294

LS_WriteParamList: Inverter motor brake:

PT1 filter time

Linear value

22281

5709

A

4

INTEGER_16

10

C02295

LS_WriteParamList: Flying restart fct.:

activation

Selection list

22280

5708

A

4

UNSIGNED_8

1 CINH

C02296

LS_WriteParamList: Flying restart fct.:

process

Selection list

22279

5707

A

4

UNSIGNED_16

1

C02297

LS_WriteParamList: Flying restart: start

frequency

Linear value

22278

5706

A

4

INTEGER_16

1

C02298

LS_WriteParamList: Flying restart fct: int.

time

Linear value

22277

5705

A

4

UNSIGNED_16

10

C02299

LS_WriteParamList: Flying restart fct.:

current

Linear value

22276

5704

A

4

INTEGER_16

100

C02300

LS_WriteParamList: SLPSM: Controlled

current setpoint

Linear value

22275

5703

A

8

UNSIGNED_16

100

C02301

LS_WriteParamList: SLPSM: Switching

speed

Linear value

22274

5702

A

8

INTEGER_16

100

C02302

LS_WriteParamList: SLPSM: Filter time -

rotor position

Linear value

22273

5701

A

4

INTEGER_16

100

C02303

LS_WriteParamList: SLPSM: Filter time

rotor position

Linear value

22272

5700

A

8

INTEGER_16

10

C02304

LS_WriteParamList: SLPSM: PLL gain

Linear value

22271

56FF

A

4

INTEGER_16

1

C02305

LS_WriteParamList: PSM: Ppp saturation

characteristic

Linear value

22270

56FE

A

68

UNSIGNED_8

1

C02306

LS_WriteParamList: PSM: Imax Ppp

saturation characteristic

Linear value

22269

56FD

A

4

UNSIGNED_16

10

C02307

LS_WriteParamList: PSM: Activate Ppp

saturation char.

Selection list

22268

56FC

A

4

UNSIGNED_8

1

C02311

LS_WriteParamList: PLI without motion:

Adaptation of time duration

Linear value

22264

56F8

A

4

INTEGER_8

1

C02312

LS_WriteParamList: PLI without motion

Bit coded

22263

56F7

A

4

UNSIGNED_16

1

C02313

LS_WriteParamList: PLI without motion:

Adaptation of ident angle

Linear value

22262

56F6

A

4

INTEGER_8

1

Code

Name

Type

Index

Data

dec

hex

DS

DA

DT

Factor

CINH

Grayed out = display parameter (read access only)