16 parameter reference – Lenze 8400 User Manual

Page 1092

Advertising
background image

16

Parameter reference

16.3

Table of attributes

1092

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00572

Brake resistor overload threshold

Linear value

24003

5DC3

E

1

UNSIGNED_8

1

C00574

Resp. to brake resist. overtemp.

Selection list

24001

5DC1

E

1

UNSIGNED_8

1

C00576

SC: Field feedforward control

Linear value

23999

5DBF

E

1

UNSIGNED_16

1

C00577

SC: Vp field weakening controller

Linear value

23998

5DBE

E

1

UNSIGNED_16

10000

C00578

SC: Tn field weakening controller

Linear value

23997

5DBD

E

1

UNSIGNED_16

10

C00579

Resp. to max. speed/output freq. reached

Selection list

23996

5DBC

E

1

UNSIGNED_8

1

C00580

Resp. to operating system error

Selection list

23995

5DBB

A

1

UNSIGNED_8

1

C00581

Resp. to LS_SetError_x

Selection list

23994

5DBA

A

8

UNSIGNED_8

1

C00582

Resp. to heatsink temp.> shutdown temp.

-5°C

Selection list

23993

5DB9

E

1

UNSIGNED_8

1

C00585

Resp. to motor overtemp. PTC

Selection list

23990

5DB6

E

1

UNSIGNED_8

1

C00586

Resp. to encoder open circuit HTL

Selection list

23989

5DB5

E

1

UNSIGNED_8

1

C00587

Resp. to brake resist. overtemp. PTC

Selection list

23988

5DB4

A

1

UNSIGNED_8

1

C00588

Resp. to max. speed at switching freq.

Selection list

23987

5DB3

E

1

UNSIGNED_8

1

C00590

Resp. to switch. frequency red.

Selection list

23985

5DB1

E

1

UNSIGNED_8

1

C00592

Resp. to CAN bus connection

Selection list

23983

5DAF

A

5

UNSIGNED_8

1

C00593

Resp. to CANx_IN monitoring

Selection list

23982

5DAE

A

3

UNSIGNED_8

1

C00594

Resp. to control word error

Selection list

23981

5DAD

A

2

UNSIGNED_8

1

C00595

MCK: Resp. to MCK error

Selection list

23980

5DAC

A

15

UNSIGNED_8

1

C00597

Resp. to motor phase failure

Selection list

23978

5DAA

E

1

UNSIGNED_8

1

C00598

Resp. to I/O monitoring

Selection list

23977

5DA9

A

4

UNSIGNED_8

1

C00599

Motor phase failure threshold

Linear value

23976

5DA8

E

1

INTEGER_16

100

C00600

Resp. to DC bus voltage

Selection list

23975

5DA7

A

1

UNSIGNED_8

1

C00601

Delayed resp. to fault: DC bus overvoltage Linear value

23974

5DA6

A

1

UNSIGNED_16

1000

C00602

Resp. to earth fault

Selection list

23973

5DA5

E

1

UNSIGNED_8

1

C00606

Resp. to motor overload (I²xt)

Selection list

23969

5DA1

E

1

UNSIGNED_8

1

C00607

Resp. to max. freq. feedb. DIG12/56

Selection list

23968

5DA0

E

1

UNSIGNED_8

1

C00608

Resp. to maximum torque

Selection list

23967

5D9F

E

1

UNSIGNED_8

1

C00609

Resp. to maximum current

Selection list

23966

5D9E

E

1

UNSIGNED_8

1

C00620

System connection list: 16-bit

Selection list

23955

5D93

A

105 UNSIGNED_16

1

C00621

System connection list: Bool

Selection list

23954

5D92

A

181 UNSIGNED_16

1

C00622

System connection list: Angle

Selection list

23953

5D91

A

24

UNSIGNED_16

1

C00630

L_Limit 1-2: Min/Max

Linear value

23945

5D89

A

4

INTEGER_16

100

C00631

L_LimitPhi 1-3: Min/Max

Linear value

23944

5D88

A

6

INTEGER_32

1

C00632

L_NSet_1: Max. skip freq.

Linear value

23943

5D87

A

3

INTEGER_16

100

C00633

L_NSet_1: Min. skip freq.

Linear value

23942

5D86

A

3

INTEGER_16

100

C00634

L_NSet_1: wState

Bit coded

23941

5D85

E

1

UNSIGNED_16

1

C00635

L_NSet_1: nMaxLimit

Linear value

23940

5D84

E

1

INTEGER_16

100

C00636

L_NSet_1: nMinLimit

Linear value

23939

5D83

E

1

INTEGER_16

100

C00637

L_NSet_1: Output blocking zones

Linear value

23938

5D82

E

1

INTEGER_16

100

C00638

L_NSet_1: Output ramp rounding

Linear value

23937

5D81

E

1

INTEGER_16

100

C00639

L_NSet_1: Output add.value

Linear value

23936

5D80

E

1

INTEGER_16

100

C00640

L_NSet_1: nNOut_a

Linear value

23935

5D7F

E

1

INTEGER_16

100

C00643

Resp. to PLI monitoring

Selection list

23932

5D7C

A

1

UNSIGNED_8

1

C00650

L_Arithmetik 3-5: Function

Selection list

23925

5D75

A

3

UNSIGNED_8

1

C00653

Sensibility - Setpoint feedforward control

Selection list

23922

5D72

A

1

UNSIGNED_8

1

C00654

Source of diff. setpoint feedforward

control

Selection list

23921

5D71

A

1

UNSIGNED_8

1

C00660

L_FixSet_a_1: Analog values

Linear value

23915

5D6B

A

16

INTEGER_16

100

C00661

L_FixSet_w_1: Fixed values

Linear value

23914

5D6A

A

16

UNSIGNED_16

1

C00662

L_FixSet_w_2: Fixed values

Linear value

23913

5D69

A

16

UNSIGNED_16

1

Code

Name

Type

Index

Data

dec

hex

DS

DA

DT

Factor

CINH

Grayed out = display parameter (read access only)