C00585 | resp. to motor overtemp. ptc, C00586 | resp. to encoder open circuit htl, C00587 | resp. to brake resistor overtemp. ptc – Lenze 8400 User Manual

Page 851: C00588 | resp. to max. speed at switching freq, C00586, C00585, Is activated, Tting, Fault"), mo, C00588

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

851

16

Parameter reference

16.2

Parameter list | C00585

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00585

C00586

C00587

C00588

Parameter | Name:

C00585 | Resp. to motor overtemp. PTC

Data type: UNSIGNED_8

Index: 23990

d

= 5DB6

h

Response to motor overtemperature

• The motor temperature is measured by means of a PTC thermistor at connector X21.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00586 | Resp. to encoder open circuit HTL

Data type: UNSIGNED_8

Index: 23989

d

= 5DB5

h

Response to encoder feedback system failure or encoder feedback system track failure due to open circuit
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00587 | Resp. to brake resistor overtemp. PTC

Data type: UNSIGNED_8

Index: 23988

d

= 5DB4

h

From version 12.00.00

Response to overtemperature of the brake resistor

• The brake resistor temperature is measured by means of a PTC thermistor at connector X20.

Selection list

0 No Reaction
1 Fault
5 Warning

Subcodes

Lenze setting

Info

C00587/1

0: No Reaction

Resp. to brake resist. overtemp. PTC

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00588 | Resp. to max. speed at switching freq.

Data type: UNSIGNED_8

Index: 23987

d

= 5DB3

h

Response if the maximum speed for the set inverter switching frequency is reached (

C00018

)

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1