6i/o terminals – Lenze 8400 User Manual
Page 310
6
I/O terminals
6.1
Digital terminals
310
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Short overview of the parameters for the frequency inputs:
Parameter
Info
Lenze setting
Value Unit
Appl.: Reference speed
1500 rpm
Frequency input DI1/DI2
Fct. DI 1/2 100kHz
0: DI1(5)=In / DI2(6)=In
Encoder increments at FreqIn12
128 Incr./rev.
FreqIn12: Offset
0.00 %
FreqIn12: Gain
100.00 %
PosIn12: Function
Loading with level
PosIn12: Comparison value
0
DIx: Terminal level
-
FreqIn12_nOut_v
- Incr/ms
FreqIn12_nOut_a
- %
FreqIn12_dnOut_p
- Incr
Frequency input DI5/DI6
Fct. DI 5/6 10kHz
0: DI1(5)=In / DI2(6)=In
Encoder increments at FreqIn56
128 Incr./rev.
FreqIn56: Offset
0.00 %
FreqIn56: Gain
100.00 %
DIx: Terminal level
-
FreqIn56_nOut_v
- Incr/ms
FreqIn56_nOut_a
- %
Highlighted in grey = display parameter