Short overview of the parameters for the frequency inputs:

Parameter

Info

Lenze setting

Value Unit

C00011

Appl.: Reference speed

1500 rpm

Frequency input DI1/DI2

C00115/1

Fct. DI 1/2 100kHz

0: DI1(5)=In / DI2(6)=In

C00420/1

Encoder increments at FreqIn12

128 Incr./rev.

C02842/1

FreqIn12: Offset

0.00 %

C02843/1

FreqIn12: Gain

100.00 %

C02844/1

PosIn12: Function

Loading with level

C02845

PosIn12: Comparison value

0

C00443/1

DIx: Terminal level

-

C00445/1

FreqIn12_nOut_v

- Incr/ms

C00446/1

FreqIn12_nOut_a

- %

C00449/1

FreqIn12_dnOut_p

- Incr

Frequency input DI5/DI6

C00115/2

Fct. DI 5/6 10kHz

0: DI1(5)=In / DI2(6)=In

C00420/2

Encoder increments at FreqIn56

128 Incr./rev.

C02842/2

FreqIn56: Offset

0.00 %

C02843/2

FreqIn56: Gain

100.00 %

C00443/1

DIx: Terminal level

-

C00445/2

FreqIn56_nOut_v

- Incr/ms

C00446/2

FreqIn56_nOut_a

- %