C01051 | l_calcdiameter_1: filter time constant, C01052 | l_calcdiameter_1: web break monitoring, C01053 | l_processctrl_1: controller times – Lenze 8400 User Manual

Page 972: C01054 | l_processctrl_1: system deviation, 16 parameter reference

Advertising
background image

16

Parameter reference

16.2

Parameter list | C01051

972

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01051

C01052

C01053

C01054

Parameter | Name:

C01051 | L_CalcDiameter_1: Filter time constant

Data type: UNSIGNED_16

Index: 23524

d

= 5BE4

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0.010

s

3.000

Subcodes

Lenze setting

Info

C01051/1

1.000 s

L_CalcDiameter_1

: Filter time constant

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01052 | L_CalcDiameter_1: Web break monitoring

Data type: INTEGER_16

Index: 23523

d

= 5BE3

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C01052/1

10.00 %

L_CalcDiameter_1

: Permissible diameter change

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C01053 | L_ProcessCtrl_1: Controller times

Data type: UNSIGNED_16

Index: 23522

d

= 5BE2

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0.000

s

30.000

Subcodes

Lenze setting

Info

C01053/1

0.000 s

L_ProcessCtrl_1

: Acceleration/deceleration time

C01053/2

0.000 s

L_ProcessCtrl_1

: Filter time constant

C01053/3

0.000 s

L_ProcessCtrl_1

: Rate time

C01053/4

1.000 s

L_ProcessCtrl_1

: Reset time

C01053/5

0.000 s

L_ProcessCtrl_1

: Rate action

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01054 | L_ProcessCtrl_1: System deviation

Data type: INTEGER_16

Index: 23521

d

= 5BE1

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0.00

%

199.99

Subcodes

Lenze setting

Info

C01054/1

100.00 %

L_ProcessCtrl_1

: Gain of system deviation

C01054/2

0.00 %

L_ProcessCtrl_1

: Area of system deviation

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising