3commissioning – Lenze 8400 User Manual
Page 77
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
77
3
Commissioning
3.8
Commissioning of the "Table positioning" technology application
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Positioning
1. Requesting the "Positioning" operating mode:
• Set digital input DI5 to HIGH level to select profile 3 and at the same time request the
"Positioning" operating mode.
2. Start positioning:
• Set digital input DI6 to HIGH level ("Alternative function PosExecute").
3. Conclude positioning when the target position has been reached:
• Reset digital input DI6 to LOW level.
Tip!
The active operating mode (
) in the signal flow can also be controlled by means of
the setting of the switch in the "Motion Control Kernel" block.
Related topics:
"Inhibit at power-on" auto-start option
Trouble-shooting during commissioning
Diagnostics & error management