3commissioning – Lenze 8400 User Manual

Page 77

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

77

3

Commissioning

3.8

Commissioning of the "Table positioning" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Positioning

1. Requesting the "Positioning" operating mode:

• Set digital input DI5 to HIGH level to select profile 3 and at the same time request the

"Positioning" operating mode.

2. Start positioning:

• Set digital input DI6 to HIGH level ("Alternative function PosExecute").

3. Conclude positioning when the target position has been reached:

• Reset digital input DI6 to LOW level.

Tip!
The active operating mode (

C01243

) in the signal flow can also be controlled by means of

the setting of the switch in the "Motion Control Kernel" block.

Related topics:

"Inhibit at power-on" auto-start option

( 119)

Trouble-shooting during commissioning

( 53)

Diagnostics & error management

( 553)