Emulex Drivers Version 10.2 for VMware ESXi User Manual

P010087-01A Rev. A

3. Configuration

FC and FCoE Driver Configuration

1020

Using the OneCommand Manager Application for VMware
vCenter

The OneCommand Manager application for VMware vCenter plug-in software uses

the standard CIM interfaces to manage the adapters and supports CIM-based device

and adapter management. The OneCommand Manager application for VMware

vCenter plug-in software also supports existing adapter management functionality

based on its proprietary management stack and the standard HBAAPI interface. To

manage LightPulse and OneConnect adapters (including updating the firmware) on an

ESXi 5.0, 5.1, or 5.5 host using OneCommand Manager application for VMware

vCenter, you must install the out-of-box Emulex CIM Provider on the host.
For more information on installing the OneCommand Manager application for

VMware vCenter software plugin and enabling the CIM Provider, see the OneCommand

Manager Application for VMware vCenter User Manual.

Installing the Emulex CIM Provider

Refer to the CIM Provider Installation Guide for instructions on installing the Emulex

CIM provider.

Working with VPorts

Creating, Deleting, and Displaying VPorts

The Emulex driver for VMware supports NPIV by default. The only management API

for creating and deleting a VPort and creating an NPIV-enabled virtual machine comes

from ESXi. VPorts in the driver discover the fabric just like physical ports do, and are

subject to the same SAN delays. As the number of VPorts increases, the amount of time

it takes to complete remote port discovery increases. This is because the VPorts are

created sequentially and each VPort executes discovery synchronously. If your

NPIV-enabled virtual machines power-on automatically, powering on could take

longer than usual. This is normal for NPIV virtual machines.

Note: The following notes apply to VPorts:

Ensure you are using the latest recommended firmware for VPort functionality.

Check the Emulex website for the latest firmware.

Loop devices and NPIV are not supported on the same port at the same time. If

you are running a loop topology and you create a VPort, the VPort’s link state is

offline. VMware ESX supports only fabric mode.

You can create VPorts only on 4, 8, and 16 Gb/s LightPulse adapters, and on

OneConnect adapters. You cannot create VPorts on 1 Gb/s or 2 Gb/s adapters.

The OneCommand Manager application sees all VPorts created by the driver,

but the application has read-only access to them.