Link log messages (1302–1306) – Dell Emulex Family of Adapters User Manual

Page 682

Advertising
background image

Emulex Drivers for Windows User Manual

P010077-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

682

lpfc_mes0747: Target reset complete: PathId: x%x, TargetId: x%x, Did: x%x

lpfc_mes0748: Lun reset complete: PathId: x%x, TargetId: x%x, Lun: x%x

lpfc_mes0749: Abort task set complete: Did: x%x, SCSIId: x%x

Link Log Messages (1302–1306)

lpfc_mes1302: Invalid speed for this board:%d, forced link speed to auto

Description

A target reset operation has completed.

Severity

Warning

Log

LOG_FCP verbose

Action

Review system configuration. Possible side-effect

of cluster operations.

Remark

See also Message 0713.

Description

A LUN reset operation has completed.

Severity

Warning

Log

LOG_FCP verbose

Action

Review system configuration. Possible side-effect

of cluster operations.

Remark

See also Message 0703.

Description

A task management has completed.

Severity

Warning

Log

LOG_FCP verbose

Action

Review system configuration. Possible side-effect

of cluster operations.

Remark

See also Message 0701.

Description

The driver is re-initializing the link speed to

auto-detect.

Severity

Warning

Log

LOG_LINK_EVENT verbose

Action

None required.

Advertising