background image

OneCommand™ Manager Application

P010066-01A Rev. A

8. Managing Adapters and Ports

FC/FCoE

137

4. Click Add Binding. The Add Persistent Binding dialog box is displayed.

Figure 8-15 Add Persistent Binding Dialog Box

5. Select the bind type that you want to use (WWPN, WWNN or D_ID).
6. Select the Bus ID and target ID that you want to bind, and click OK.

Note: Automapped targets have entries only in the second column of the Targets

Table. Persistently bound targets have entries in the second and third

columns. In this case, the third column contains the SCSI Bus and target

numbers you specified in the Add Persistent Binding dialog box. This

binding takes effect only after the local machine is rebooted.

Binding a Target that Does Not Appear in the Persistent Binding
Table

Note: It is possible to specify a SCSI bus and target that have already been used on

behalf of a different FC target. Attempting to bind a target already in the

Persistent Binding table on the Target Mapping tab results in an error message,

“Target already in target list. Use the Add Binding button.”

To bind a target that does not appear in the Persistent Binding table on the Target

Mapping tab:
1. Select Host or Fabric view.
2. In the discovery-tree, select the adapter port you want to set up with persistent

binding.

3. Select the Target Mapping tab. All targets are displayed.
4. Click Bind New Target. The Bind New Target dialog box is displayed.

Figure 8-16 Bind New Target Dialog Box

Advertising