Emulex Drivers for Windows User Manual

P010077-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

681

lpfc_mes0729: FCP command error: ulpStatus: x%x, ulpWord[4]: x%x, XRI:
x%x, ulpWord[7]: x%x

lpfc_mes0730: FCP response error: Flags: x%x, SCSI status: x%x,
Residual:%d

lpfc_mes0734: Read Check: fcp_parm: x%x, Residual x%x

lpfc_mes0737: SCSI check condition, SenseKey x%x, ASC x%x, ASCQ x%x,
SrbStatus: x%x

Description

The specified device failed an I/O FCP

command.

Severity

Warning

Log

LOG_FCP verbose

Action

Check the state of the target in question.

Remarks

lpfc_mes0730 is also recorded if it is a FCP Rsp

error.

Description

The FCP command failed with a response error.

Severity

Warning

Log

LOG_FCP verbose

Action

Check the state of the target in question.

Remark

lpfc_mes0716, lpfc_mes0734, lpfc_mes0736 or

lpfc_mes0737 is also recorded for more details if

the corresponding SEVERITY level is set.

See Also

lpfc_mes0729

Description

The issued FCP command returned a Read Check

Error.

Severity

Warning

Log

LOG_FCP verbose

Action

Check the state of the target in question.

See Also

lpfc_mes0730

Description

The issued FCP command resulted in a Check

Condition.

Severity

Warning

Log

LOG_FCP verbose

Action

Review SCSI error code values.

See Also

lpfc_mes0730

Advertising