Dell Emulex Family of Adapters User Manual

Page 1069

Advertising
background image

Emulex Drivers Version 10.2 for VMware ESXi User Manual

P010087-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

1069

elx_mes0472: Unknown PCI error state: <value>

DESCRIPTION: The PCI bus has detected an error.
DATA: (1) state value
ACTION: Driver resets the adapter and attempts recovery. If the issue persists, contact

Emulex technical support.

elx_mes0474: Unable to allocate memory for issuing "MBOX_CONFIG_MSI
command”

DESCRIPTION: Mailbox memory pool allocation error.
DATA: None
ACTION: None required.

elx_mes0475: Not configured for supporting MSI-X cfg_use_msi:
<cfg_use_msi>.

DESCRIPTION: The lpfc_use_msi module parameter should have been set to 2.
DATA: None
ACTION: Set module parameter lpfc_use_msi=2.

elx_mes0476: HBA not supporting SLI-3 or later SLI Revision: <sli_rev>.

DESCRIPTION: The adapter does not support SLI-3 or SLI-4.
DATA: None
ACTION: This adapter does not support MSI. Set lpfc_use_msi=0.

elx_mes0479: Deferred Adapter Hardware Error

DESCRIPTION: An adapter hardware error was sent to the driver.
DATA: (1) work_hs, (2) work_status[0], (3) work_status[1]
ACTION: Perform a dump using hbacmd.

elx_mes0482: Illegal interrupt mode

DESCRIPTION: Driver could not set MSI-X, MSI or INTX interrupt modes.
DATA: None
ACTION: This could be a server issue. Reboot. If this issue persists, report these errors

to Emulex technical support.

elx_mes0483: Invalid link-attention link speed: <value>,
bf_get(lpfc_acqe_link_speed, acqe_link).

DESCRIPTION: The link speed reported in the link attention interrupt is invalid.
DATA: None
ACTION: Check the switch configuration.

Advertising