Phy data tab field definitions, Figure 6-51 – Dell Emulex Family of Adapters User Manual

Page 1265

Advertising
background image

OneCommand Manager for VMware vCenter Version 10.2 User Manual

P010089-01A Rev. A

6. Managing Adapters and Ports

OCe10100–Series and OCe11100–Series Adapters

1265

Figure 6-51 OneConnect Adapter PHY Data Tab

PHY Data Tab Field Definitions

Operational Attributes Area

Temperature – The internally measured adapter temperature.

Firmware – The version of Emulex firmware currently active on the adapter

port.

Config ID – The CRC configuration details.

Link Uptime – The time in seconds that the link has been up. Pair A/B/C/D

SNR Margin – The port’s average SNR margin for twisted pairs A, B, C & D.

Error Rates Area

LDPC Frame Errors – The number of LDPC frame errors.

PHY CRC8 Errors – The number of physical CRC errors.

Pair A/B/C/D MSE – The port’s average MSE relative to the transmitted code

words for twisted pairs A, B, C & D.

Counters Area

MDI PLL Events – The number of MDI PLL events.

10G EMI Events – The 10G EMI Event counter tracks the number of single-tone

interference detected by the CNA's MDI signals. This counter holds its value at

MDI link down and self-clears at the next link up.

PHY Frames – Counts the number of physical frames transmitted and received

since the MDI link has been established. This counter holds its value at MDI link

down and self-clears at the next link up.

Advertising