Nic adapter firmware error – Dell Emulex Family of Adapters User Manual

Page 1135

Advertising
background image

Emulex Drivers Version 10.2 for VMware ESXi User Manual

P010087-01A Rev. A

4. Troubleshooting

Troubleshooting the NIC Driver

1135

NIC Adapter Firmware Error

The following POST message appears if you have loaded firmware on the adapter that

the controller does not support:

POST Error : Firmware halted. This firmware does not support this

controller.

Warning

Invalid MTU requested. MTU must

be between 64 and 9000 bytes.

Invalid MTU size in MTU
configuration IOCTL. The MTU will
not be changed.

Warning

Invalid vlan priority labeled.

Must be 0 - 7

A request to set a VLAN priority tag
was made with an invalid value.

Warning

Failed to allocate memory for

pass through command

The memory allocation for a pass
through command failed. The driver
will continue to function. The
configuration utility that issued the
pass through IOCTL will fail.

Warning

Pass through command failed.

opcode <DDD>, status 0x<XXX>

The pass through firmware command
with the indicated opcode failed.
The driver should continue to
function. The configuration utility
that issued the pass through IOCTL
will fail.

Warning

Command to modify EQ delay

failed

The firmware command to change
the EQ delay failed. The driver will
continue to function. Adaptive
interrupt coalescing does not
function correctly.

Table 4-5 ESXi Server NIC Event Log Entries (Continued)

Severity

Displayed Message

Description

Advertising