Tag messages (1400–1401) – Dell Emulex Family of Adapters User Manual

Page 683

Advertising
background image

Emulex Drivers for Windows User Manual

P010077-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

683

lpfc_mes1303: Link Up event: tag: x%x, link speed:%dG, topology (0 =
Pt2Pt, 1 = AL):%d

lpfc_mes1305: Link down even: tag x%x

lpfc_mes1306: Link Down timeout

Tag Messages (1400–1401)

lpfc_mes1400: Tag out of range: ContextIndex: x%x, MaxIndex: x%x,
ulpCommand: x%x

Description

A link up event was received. It is also possible

for multiple link events to be received together.

Severity

Error

Log

LOG_LINK_EVENT verbose

Action

If numerous link events are occurring, check

physical connections to the FC network.

Remarks

lpfc_mes1304 is recorded if Map Entries > 0 and

the corresponding mode and SEVERITY level is

set.

Description

A link down event was received.

Severity

Error

Log

LOG_LINK_EVENT verbose

Action

If numerous link events are occurring, check

physical connections to the FC network.

Description

The link was down for greater than the

configuration parameter (HLinkTimeOut)

seconds. All I/O associated with the devices on

this link will be failed.

Severity

Warning

Log

LOG_LINK_EVENT verbose

Action

Check adapter cable/connection to SAN.

Description

Firmware has generated an invalid response.

Severity

Error

Log

LOG_LINK_EVENT verbose

Action

Review hardware configuration. Contact Emulex

Technical Support.

Advertising