912

0483:Invalid link-attention link speed: x%x", bf_get(lpfc_acqe_link_speed,

acqe_link).

The link speed reported in the link attention interrupt is invalid.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

Check the switch configuration.

0485: MSI-X slow-path request_irq failed (<rc>).

The request_irq kernel API has failed.

Data:

None

Severity: Warning
Log:

LOG_INIT

Action:

Set module parameter lpfc_use_msi=0.

0486: MSI-X fast-path (<index>) request_irq failed (<rc>).

The request_irq kernel API has failed.

Data:

None

Severity: Warning
Log:

LOG_INIT

Action:

Set module parameter lpfc_use_msi=0.

0490: MSI request_irq failed (<rc>).

The request_irq kernel API has failed.

Data:

None

Severity: Warning
Log:

LOG_INIT

Action:

Set module parameter lpfc_use_msi=0.

0492: Unable to allocate memory for issuing SLI_CONFIG_SPECIAL mailbox command

Mailbox memory pool allocation error.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

0493: SLI_CONFIG_SPECIAL mailbox failed with status<rc>

Mailbox command failed.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

Ensure the adapter’s firmware is current. Unload and reload the driver.

0494: Unable to allocate memory for issuing "SLI_FUNCTION_RESET mailbox

command"

Mailbox memory pool allocation error.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.