OneCommand™ Manager Application

P010066-01A Rev. A

13. Diagnostics

LightPulse FC HBA Diagnostics

268

provides the ability to diagnose marginal cable conditions (e.g. dust in the

optics) that result in higher error rates.

D_Port should not be enabled on the switch port.

D_Port tests run with the physical connection in an offline diagnostic state, so

normal I/O cannot be sent through the physical port while the test is in

progress. While the port is in D_Port mode, the link will appear down on that

port; similar to an unplugged cable.

When using D_Port in a boot from SAN configuration, the configuration must

have redundant paths to the boot LUN and only one of the redundant adapter

ports should be set to D_Port.

For more information about D_Port, refer to the Brocade website at

www.brocade.com.

D_Port is also referred to as ClearLink.

The D_Port Tests button on the Diagnostics tab enables you to run D_Ports tests on

LPe16000 series adapters.

Figure 13-4 Diagnostics Tab for LPe16000 series adapters (D Port Tests... button depicted)

To run a D_Port test:
1. From the discovery-tree, select the LPe16000 series adapter port on which you want

to run the D_Port test.

2. Select the Diagnostics tab and click D_Port Tests... The D_Port Tests window

appears.