900

0368: Mis-matched fast-path completion queue identifier: eqcqid=%d, fcpcqid=%d

The CQID in the event queue entry does not match the fcp_cqid that was passed into the routine.

Data:

None

Severity: Error
Log:

LOG_SLI

Action:

None required.

0369: No entry from fast-path completion queue fcpcqid=<queue_id>

There were no completions in the completion queue referenced by fcp_cqid.

Data:

None

Severity: Error
Log:

LOG_SLI

Action:

None required.

0370: Invalid completion queue type <type>

The event queue entry is not for a mailbox or a work queue entry.

Data:

None

Severity: Error
Log:

LOG_SLI

Action:

None required.

0371: No entry from the CQ: identifier <queue_id>, type <type>

There was no completion queue event for this event queue entry.

Data:

None

Severity: Error
Log:

LOG_SLI

Action:

None required.

0372: iotag <iotag> is out of range: max iotag (<sli.last_iotag>)

The IOCB lookup cannot be performed because the iocb_tag is out of range.

Data:

None

Severity: Error
Log:

LOG_SLI

Action:

None required.

0373: FCP complete error: status=<status> hw_status=<hw status>,

total_data_specified=<total data transferred>, parameter=<rsp word[4]>,

word3=<wcqe word 3>

Logs the FCP failure. Status and parameter are equivalent to ulpStatus and ulpWord[4].

Data:

None

Severity: Warning
Log:

LOG_SLI

Action:

None required.

0374: FCP complete with no corresponding cmdiocb: iotag <iocb iotag>

There was no IOCB on the in-progress list that matched this iotag.

Data:

None

Severity: Warning
Log:

LOG_SLI

Action:

None required.

Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)

Advertising