FCoE End to End Echo Test

The end-to-end test enables you send an ECHO command/response sequence between

an adapter port and a target port. (Not available on ESXi systems.)

Note: Not all remote devices respond to an echo command. You cannot run the ECHO

test and the External Loopback test concurrently. If you select the ECHO Test

the External Loopback test is disabled.

Error Action

Enables you to define what is to be done in the event of a test failure. There are two

error action options:

Stop Test – Do not log the error and abort the test. No further tests are run.

Ignore – Log the error and proceed with the next test cycle.

Test Cycles

Enables you to specify test cycles three ways:

Select an established cycle count by clicking on the corresponding radio button.

Enter a custom cycle count in the blank field in the Test Cycles area.

Set the test to run until you manually click Stop Test, by selecting the Infinite

radio button.

Test Pattern

Enter a custom test pattern to be used in tests that transfer data. The test pattern can be

up to 8 hexadecimal bytes.

Test Status

The Test Status area displays how many completed cycles of each test ran, as well as the

number of errors.
To run loopback tests:
1. From the discovery-tree, select the adapter port on which you want to run the

Loopback Test.

2. Select the Diagnostics tab. From the Loopback Test section of the dialog box,

choose the type of Loopback test you want to run and define the loopback test

parameters.

Note: You must insert a loopback plug in the selected adapter before running an

External Loopback test. Also, you must ensure that the NIC function of the

port goes to a link up state. See the Troubleshooting section if the NIC link

fails to come up.