OneCommand Manager Command Line Interface Version 10.2 User Manual

P010067-01A Rev. A

5. CLI Client Command Descriptions

Profile Management Commands

418

NIC+RoCE

>hbacmd getadapterportconfig 00-00-c9-12-34-56

Number of Ports : 4

Maximum FCoE Functions : 4

Maximum iSCSI Functions : 4

Mixed Mode I/O Allowed : Yes

Concurrent Mode I/O Allowed : Yes

ROCE Functions Allowed : Yes

RebootRequired : No

Active Configuration

Profile ID : 21

MC Type : None

Port Assignments:

Port 0: NIC+RoCE,None,None

Port 1: NIC,None,None

Port 2: NIC+RoCE,None,None

Port 3: NIC,None,None

Reboot Configuration

Profile ID : 21

MC Type : None

Port Assignments:

Port 0 (p0): NIC+RoCE,None,None

Port 1 (p1): NIC,None,None

Port 2 (p2): NIC+RoCE,None,None

Port 3 (p3): NIC,None,None

Note:(pN) labels are the port parameter names to use in the

SetAdapterPortConfig command (e.g. p0=NIC,FCoE p1=NIC,iSCSI).

ListProfiles

This command shows a list of the available profile IDs and their descriptions for an

adapter including the currently active and configured profile IDs. This information

helps to determine the appropriate profile ID to specify to the ChangePersonality and

SetAdapterPortConfig commands required for RoCE and NIC-only configurations. The

specific profiles listed may vary according to the adapter model.

Note: RoCE is only available on Windows operating systems.