Dell Emulex Family of Adapters User Manual

Page 903

Advertising
background image

Emulex Drivers Version 10.2 for Linux User Manual

P010081-01A Rev. A

4. Troubleshooting

Log Messages

903

0394: Failed to allocate CQ_EVENT entry

The asynchronous event handler was unable to allocate an event queue entry to which to transfer
the asynchronous event.

Data:

None

Severity: Error
Log:

LOG_MBOX, LOG_SLI

Action:

This could be a V-LINK clear from the switch or a fatal error from the firmware. Perform
a dump from the OneCommand Manager application.

0395: The mboxq allocation failed

The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA
(read link attention) mailbox command.

Data:

None

Severity: Error
Log:

LOG_SLI

Action:

None required.

0396:The lpfc_dmabuf allocation failed

The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA
mailbox command.

Data:

None

Severity: Error
Log:

LOG_SLI

Action:

None required.

0397:The mbuf allocation failed

The asynchronous link event handler could not allocate DMA-able memory for the READ_LA mailbox
command.

Data:

None

Severity: Error
Log:

LOG_SLI

Action:

None required.

0398 Invalid link fault code: <hex link_fault>

The attempt to read the link attention register has returned an unknown value.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

0399 Invalid link attention type: <hex link_type>

The READ_LA mailbox command has returned an invalid link type.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required