Dell Emulex Family of Adapters User Manual

Page 1115

Advertising
background image

Emulex Drivers Version 10.2 for VMware ESXi User Manual

P010087-01A Rev. A

4. Troubleshooting

Troubleshooting the FC/FCoE Driver

1115

ACTION: If the issue persists, report the error to Emulex technical support.

elx_mes2753: PLOGI failure DID:<DID> Status:<Status>/<Extended Status>.

DESCRIPTION: A PLOGI to <DID> was failed either by the driver, firmware, or target.

The <status> and <extended status> indicates why the PLOGI failed.
DATA: None
ACTION: If the issue persists, report the error to Emulex technical support.

elx_mes2754: PRLI failure DID:<DID> Status:<Status>/<Extended Status>.

DESCRIPTION: A PRLI to <DID> was failed either by the driver, firmware, or target.

The <status> and <extended status> indicates why the PRLI failed.
DATA: None
ACTION: If the issue persists, report the error to Emulex technical support.

elx_mes2755: ADISC failure DID:<DID> Status:<Status>/<Extended Status>.

DESCRIPTION: A ADISC to <DID> was failed either by the driver, firmware, or target.

The <status> and <extended status> indicates why the ADISC failed.
DATA: None
ACTION: If the issue persists, report the error to Emulex technical support.

elx_mes2756: LOGO failure DID:<DID> Status:<Status>/<Extended Status>.

DESCRIPTION: A LOGO to <DID> was failed either by the driver, firmware, or target.

The <status> and <extended status> indicates why the LOGO failed.
DATA: None
ACTION: If the issue persists, report the error to Emulex technical support.

elx_mes2757: Protocol failure detected during processing of FCP I/O op:
tgt <tgt ID> lun <LUN> cmnd <CMD> rspInfo3 <rspInfo3>

DESCRIPTION: The FCP response from a target indicated that the response length is

valid, but rspInfo3 indicates that there is no Failure. This is a FCP specification violation

by the target.
DATA: None
ACTION: If the issue persists, report the error to Emulex technical support.

elx_mes2758: Failed to allocate mbox for READ_FCF command.

DESCRIPTION: The driver failed to allocate memory from the mempool for issuing

FCF read mailbox command during the round robin FCF bmask update.
DATA: None
ACTION: None required.