Dell Emulex Family of Adapters User Manual
Page 721
Emulex Drivers for Windows User Manual
P010077-01A Rev. A
Appendix A. Error and Event Log Information
iSCSI Error and Event Log
721
0x4d
Warning
Connection was invalidated
internally; the command and
data were not on the same
connection.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.
0x4e
Warning
Solicited command was
invalidated internally due to
DIF warning.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.
0x4f
Warning
Connection was invalidated
internally due to an incoming
unsolicited PDU that had
immediate data on the
connection that does not
support it.
This condition is detected by the OneConnect
firmware. If this message is unexpected, please
check your iSCSI configuration.
Table A-15 iSCSI Error Log Entries on Windows 7, Windows 8, Windows 8.1, Windows Server 2008 R2, Windows
Server 2012, and Windows Server 2012 R2 (Continued)
Message ID
Severity
Message
Recommended Resolution