Emulex Drivers for Windows User Manual

P010077-01A Rev. A

Appendix A. Error and Event Log Information

FC/FCoE Error and Event Logs

702

Local Reject Status Codes

Codes supplied by the Emulex adapter firmware which indicate why a command was

failed by the adapter.

SRB Status Codes

SCSI Request Block status provided by the driver to the operating system based upon

response from SCSI device in the SAN.

ASC/ASCQ

Additional Sense Code/Additional Sense Code Qualifier information can be found in

any SCSI specification document – these codes contain detailed information about the

status/condition of the SCSI device in question.

Table A-10 Local Reject Status Codes

Explanation

Code

SEQUENCE TIMEOUT – Possible bad cable/link noise

0x02

INVALID RPI – Occurs when link goes down

0x04

NO XRI – Possible host or SAN problem

0x05

TX_DMA FAILED – Possible host system issue

0x0D

RX_DMA FAILED

Possible host system issue

0x0E

ILLEGAL FRAME – Possible bad cable/link noise

0x0F

NO RESOURCES – Port out of exchanges or logins

0x11

LOOP OPEN FAILURE – FC_AL port not responding

0x18

LINK DOWN – Queued cmds returned at link down

0x51A

OUT OF ORDER DATA – Possible bad cable or noise

0x1D

Table A-11 SRB Status Codes

Explanation

Code

ERROR

0x04

BUSY

0x05

TIMEOUT

0x09

SELECTION TIMEOUT

0x0A

COMMAND TIMEOUT

0x0B

BUS RESET

0x0E

DATA OVERUN

0x12

Advertising