Fip tab field descriptions, Figure 6-16 – Dell Emulex Family of Adapters User Manual

Page 1214

Advertising
background image

OneCommand Manager for VMware vCenter Version 10.2 User Manual

P010089-01A Rev. A

6. Managing Adapters and Ports

Viewing and Managing FC/FCoE LUNs

1214

.

Figure 6-16 FCoE Port FIP Tab

FIP Tab Field Descriptions

DCB Settings Area

DCB settings are only applicable when the DCBX Mode in the DCB tab is set to DCB.

Note: In Figure 6-16, the “DCB (FIP) Settings” area has “Active” in its title. This

indicates that DCB (FIP) is the current DCBX mode (DCBX mode is set from the

DCB tab). If CIN (Non-FIP) was the current DCBX mode, “Active” would be in

the “CIN (Non-FIP) Settings” area.

Primary Fabric Name – Indicates the FC fabric's WWN to which to connect. If

the Primary Fabric Name is wild (all 0xFFs), then connection to any fabric name

is allowed.

Primary Switch Name – Indicates the FC switch's WWN to which to connect. If

the Primary Switch Name is wild (all 0xFFs) then connection to any switch

name is allowed.

VLAN ID – Determines the VLAN where the adapter FCoE services are

available. It can have a value from 0 to 4095 and supports wild card values if the

Any VLAN ID is valid checkbox is selected.

Any VLAN ID is valid checkbox – When checked, the VLAN ID field of the

FCoE forwarder can be any valid value.

CIN Settings Area

FC Map – Enter the bit value that completes the fabric-provided MAC address

(FPMA).

VLAN ID – Determines the VLAN where the adapter FCoE services are

available. It can have a value from 0 to 4095.

FIP Tab Buttons

Apply Changes – Click to set new FIP parameters.