Changing automapping settings – Dell Emulex Family of Adapters User Manual

Page 135

Advertising
background image

OneCommand™ Manager Application

P010066-01A Rev. A

8. Managing Adapters and Ports

FC/FCoE

135

and SCSI ID can change when the system is rebooted. With persistent binding applied

to one of these targets, the WWPN, SCSI Bus and SCSI ID remain the same when the

system is rebooted. (Not available in read-only mode.)
The driver refers to the binding information at during system boot. When you create a

persistent binding, the OneCommand Manager application tries to make that binding

dynamic. However, the binding must meet all of the following criteria to be dynamic:

The SCSI ID (target/bus combination) specified in the binding request must not

be mapped to another target. For example, the SCSI ID must not already appear

in the 'Current Mappings' table under 'SCSI ID'. If the SCSI ID is already in use,

then the binding cannot be made dynamic, and a reboot is required.

The target (WWPN, WWNN or DID) specified in the binding request must not

be mapped to a SCSI ID. If the desired target is already mapped, then a reboot is

required.

The bind type (WWPN, WWNN or DID) specified in the binding request must

match the currently active bind type shown in the Current Settings area of the

Target Mapping tab. If they do not match, then the binding cannot be made

active.

Changing Automapping Settings

To change automapping settings:
1. Select Host or Fabric view.
2. In the discovery-tree, select the adapter port you want to set up with persistent

binding.