Dell Emulex Family of Adapters User Manual

Page 913

Advertising
background image

Emulex Drivers Version 10.2 for Linux User Manual

P010081-01A Rev. A

4. Troubleshooting

Log Messages

913

0495: SLI_FUNCTION_RESET mailbox failed with status <shdr_status> add_status

<shdr_add_status>, mbx status <rc>.

Mailbox command failed.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

Reset the HBA.

0496: Failed allocate slow-path EQ

The event queue for the slow path was not allocated.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

Unload and reload the driver.

0497: Failed allocate fast-path EQ

The event queue for the fast path was not allocated.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

Unload and reload the driver.

0499: Failed allocate fast-path FCP CQ (<fcp_cqidx>).

The completion queue event for the fast path could not be allocated.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

Unload and reload the driver.:

0500: Failed allocate slow-path mailbox CQ

Failed to allocate slow-path mailbox CQ.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

0501: Failed allocate slow-path ELS CQ

Failed to allocate slow-path ELS CQ.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

0503: Failed allocate fast-path FCP

Failed to allocate fast-path FCP.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)

Advertising