Event Trace Messages
ELS Log Messages (0100–0130)
lpfc_mes0100: FLOGI failure – ulpStatus: x%x, ulpWord[4]:x%x
lpfc_mes0101: FLOGI completes successfully – NPortId: x%x, RaTov: x%x,
EdTov: x%x
lpfc_mes0102: PLOGI completes to NPortId: x%x
lpfc_mes0103: PRLI completes to NPortId: x%x, TypeMask: x%x,
Fcp2Recovery: x%x
Description
An ELS FLOGI command that was sent to the
fabric failed.
Severity
Error
Log
LOG_ELS verbose
Action
Check the fabric connection.
Description
An ELS FLOGI command that was sent to the
fabric succeeded.
Severity
Information
Log
LOG_ELS verbose
Action
No action needed, informational.
Description
The adapter performed an N PLOGI into a
remote NPort.
Severity
Information
Log
LOG_ELS verbose
Action
No action needed, informational.
Description
The adapter performed a PRLI into a remote
NPort.
Severity
Information
Log
LOG_ELS verbose
Action
No action needed, informational.