Help (/h or /?), Image directory change (/id), Help (/h or /?) image directory change (/id) – Dell Emulex Family of Adapters User Manual

Page 473

Advertising
background image

Offline and Online Adapter Management Utilities Version 10.2 User Manual

P010071-01A Rev. A

3. Adapter Management Utility Command Line Interface

Help (/h or /?)

473

If multiple versions of firmware and boot code are found for an adapter,

Elxflash uses the most recent versions when performing the firmware and boot

code downloads.

The flash executable file is used to download firmware to supported UCNAs.

Example usage:

./elxflash /f /fo

– Forces a firmware and boot code download using the

fwmatrix.txt file, and downloads the firmware to supported UCNAs using the flash

executable file.

For each installed and supported adapter, a forced download of firmware and

boot code occurs using the versions specified in the fwmatrix.txt file.

The flash executable file is used to download firmware to supported UCNAs.

Help (/h or /?)

Usage:

/h

or

/?

The help switch displays a help message detailing instructions on how to use the

Adapter Management Utility.

Image Directory Change (/id)

Usage:

/id=<image_directory>

The image directory switch is used to specify the location of the firmware and boot

code directories.
Example usage:

./elxflash /f /auto /id=/tmp

– Forces a firmware and boot code download using

auto-discovery. Elxflash looks for the firmware and boot code directories in the /tmp

directory.

The fwmatrix.txt file is ignored. The desired versions of firmware and boot code

must be placed in their respective directories.

In this example firmware must be placed in the /tmp/firmware directory and

boot code must be placed in the /tmp/boot directory.

If multiple versions of firmware or boot code are found for an adapter, Elxflash

uses the most recent versions when performing the firmware and boot code

downloads.

./elxflash /f /i=/tmp

– Forces a firmware and boot code download using the

fwmatrix.txt file. Elxflash look for the firmware and boot code directories in the /tmp

directory.

For each installed and supported adapter, a forced download of firmware and

boot code occurs using the versions specified in the fwmatrix.txt file.

In this example firmware must be placed in the /tmp/firmware directory and

boot code must be placed in the /tmp/boot directory.

Advertising