Enabling or disabling edd 3.0, Enabling or disabling the start unit command, Figure 6-18 – Dell Emulex Family of Adapters User Manual

Page 1590

Advertising
background image

Boot Version 10.2 for NIC, iSCSI, FCoE, and RoCE Protocols User Manual

P010097-01B Rev. A

6. Using the FCoE Boot BIOS Utility for x86 and x64 Architectures

Configuring Advanced Adapter Parameters

1590

Enabling or Disabling EDD 3.0

EDD 3.0 provides additional data to the operating system boot loader during an

INT-13h function 48h call (get device parameters). This information includes the path

to the boot device and the disk size. The default setting for EDD 3.0 is enabled. When

EDD 3.0 is disabled, the setting reverts to EDD 2.1.
To enable or disable EDD 3.0:
1. From the main configuration menu (Figure 6-2), select Configure Advanced

Adapter Parameters and press <Enter>. The adapter configuration menu is

displayed (Figure 6-13).

2. Select Enable or Disable EDD 3.0 and press <Enter>. The EDD 3.0 configuration

screen is displayed.

Figure 6-18 Enable or Disable EDD 3.0 Screen

3. Select whether to enable or disable EDD 3.0.
4. Press <Enter> to accept the change.
5. Press <Esc> to return to the advanced adapter configuration menu.
6. For changes to take effect, reboot the system.

Enabling or Disabling the Start Unit Command

You must know the specific LUN to issue the SCSI start unit command. The default

setting is disabled.
To enable or disable the start unit command:
1. From the main configuration menu (Figure 6-2), select Configure Advanced

Adapter Parameters and press <Enter>. The adapter configuration menu is

displayed (Figure 6-13).

2. Select Enable or Disable Start Unit Command and press <Enter>. The Start Unit

Command configuration screen is displayed.