Booting the system – Dell Emulex Family of Adapters User Manual

Page 1621

Advertising
background image

Boot Version 10.2 for NIC, iSCSI, FCoE, and RoCE Protocols User Manual

P010097-01B Rev. A

10. Configuring and Managing iSCSI Targets with the iSCSISelect Utility

Managing an iSCSI Target

1621

To log out of a target, from the iSCSI Target Configuration screen, select the target and

press <F6>.
To log into a target, from the iSCSI Target Configuration screen, select the target and

the disconnected target, and then press <F5> to establish the target session.

Booting the System

After you have configured the iSCSI initiator and target, you must reboot the system

for the configurations to take effect. When you exit the iSCSISelect utility, the system

automatically reboots and during system startup, the Emulex adapter BIOS is

displayed. For example:

Controller#0 Port#0 Base 0xFCE60000 at Bus:01 Dev:00 Fun:02

Controller#0 Port#1 Base 0xFCEA0000 at Bus:01 Dev:00 Fun:03

<<< Press <Ctrl><S> for iSCSISelect(TM) Utility >>>

Initiator iSCSI Name: iqn.2004-05.com.emulex

Initiator IP Address: 172. 40. 1.41

Initiator IP Address: 172. 40. 1.62

BIOS Not Installed.

Note: The iSCSI BIOS logs into the configured iSCSI boot target and shows its

target/LUN information in the BIOS sign-on banner only if you have

configured an iSCSI boot target. For more information, see “Setting Up a Basic

iSCSI Boot Configuration” on page 1596.