Extended Timeout Expired. Loss of

connection to target exceeded ETO

limits.

Session ID = 0xX

Check the connection to the target or the state of the
target device. If the target is made available, any
sessions that existed previously will be reestablished and
the devices will be available for I/O.

Initialization Failure

This failure may be due to the firmware not being
present or running currently. This failure may also
indicate a hardware issue.

Initialization failure during

Power Management Bootup

This failure may be due to the firmware not being
present or running currently. This failure may also
indicate a hardware issue.

Internal API failed during

Initialization

This failure may indicate a low memory condition.

Hardware Initialization Failed.

Either Hardware/Firmware is not

initialized or is malfunctioning.

This failure indicates that the hardware has not been
initialized or is malfunctioning. This may also indicate
that the firmware is not running correctly.

LinkDown Timeout Expired. Please

check the Physical Link to

OneConnect.

Check the links to the adapter. If the link is
reestablished, any sessions that existed previously will
be reestablished and the devices will be available for
I/O.

OSM Hardware Initialization

Failure

This failure indicates that the hardware has not been
initialized or is malfunctioning. This may also indicate
that the firmware is not running correctly.

OSM Resource Allocation Failure

The operating system failed to allocate resources for the
device. Check low memory conditions and operating
system hardware resource conflicts.

Received a TMF Abort for an I/O

that is not present with the

driver.

This may indicate a slow connection to the target. Check
network connectivity to the target for any errors.

Received invalid iSCSI Command

Sequence Number update from

Target.

Session Handle = 0xX

MaxCmdSN = 0xX

ExpCmdSN = 0xX

Check for any errors reported at the target. The Emulex
iSCSI initiator is only supported with certified targets.
Check for software updates at the target vendor’s
website and the Emulex website. If this fails, contact
technical support.

Received unsupported Task

Management Function.

Task Management Function code = 0xX

The operating system version is not supported.

Rejected IOCTL since buffer size

limit exceeded.

Subsystem / Opcode = 0xX / 0xX

Payload Length = 0xX

This error may indicate an incorrect configuration option
for the iSCSI driver. It may also indicate a low memory
condition.

Table A-3 iSCSI Driver Error Log Messages (Continued)

iSCSI Error Log Message

Description

Advertising